Cables

DataGuard® from Belcom

DataGuard® coaxial cables are the industrial version incorporating various armour types according to application. The original high-performance network cables are protected by a layer of steel in the form of galvanised wire applied around the cable with an enhanced performance outer sheath for further protection.

For traditional industrial protection in fixed installations, single wire armour is used. For flexible and high vibration installations, galvanised steel wire braid is applied, and special applications of interlocking galvanised steel wire tape or overlapping steel tapes can be used for flexibility and rodent/termite protection.

RG223/U 50 Ohm

DataGuard® Armoured (SWA) MIL-C-1 JF 98% Braid LSZH Firefighter®

Electrical Properties

Inner Conductor DC 28.0  Ohm/LM
Outer Conductor DC 8.0 MOhm*km
Impedance 50±2 Ohm
Capacitance 100 pF/m
Velocity ratio 99 %
Screening effectiveness 100-900 MHz 70 dB

Transit Qualified Cables

Transit qualifications

Cable TypeTestDateTest HouseCustomerDescription
LMR 195 FRIEC 60332-3-24 Cat C23/03/2011ExovaDanish RailVertical Flame propogation
LMR 195 FRBS EN 61034-2 (2005)14/03/2011ExovaDanish RailSmoke Density
LMR 200 FRLUL code of practice comprises:20/11/1995LULLondon UndergroundSmoke , Toxic Fume , Flammability
LMR 200 FRBS 6853 : 1987 App A - Flammability
LMR 200 FRBS 6853 : 1987 App B.5.5 - Smoke
LMR 200 FR6220-05-601 - Toxic Fume Emission
LMR 240 FRBS EN 61034-2 (2005) / LUL 1-085 Iss330/05/2014InterscienceThales / CrossrailSmoke Density
LMR 240 FRBS EN 60332-3-25 / LUL 1-085 Clause 3.3.3.130/05/2014InterscienceThales / CrossrailVertical Flame propogation
LMR 240 FRLUL code of practice comprises:20/11/1995LULLondon UndergroundSmoke , Toxic Fume , Flammability
LMR 240 FRBS 6853 : 1987 App A - Flammability
LMR 240 FRBS 6853 : 1987 App B.5.5 - Smoke
LMR 240 FR6220-05-601 - Toxic Fume Emission
LMR 240-75 FRIEC 60332-3-24 Cat C23/03/2011ExovaDanish RailVertical Flame propogation
LMR 400 FRBombardier SMP-800C Rev 69/07/2015Exova USBombardier USToxic Fume
LMR 400 FRLUL code of practice comprises:20/11/1995LULLondon UndergroundSmoke , Toxic Fume , Flammability
LMR 400 FRBS 6853 : 1987 App A - Flammability
LMR 400 FRBS 6853 : 1987 App B.5.5 - Smoke
LMR 400 FR6220-05-601 - Toxic Fume Emission
LMR 400 FR-DBBS EN 60332-3-25 / LUL 1-085 Clause 3.3.3.130/05/2014InterscienceThales / CrossrailVertical Flame propogation
LMR 400 FR-DBBS EN 61034-2 (2005) / LUL 1-085 Iss330/05/2014InterscienceThales / CrossrailSmoke Density
CCTV 400-75-FRLUL code of practice comprises:20/11/1995LULLondon UndergroundSmoke , Toxic Fume , Flammability
CCTV 400-75-FRBS 6853 : 1987 App A - Flammability
CCTV 400-75-FRBS 6853 : 1987 App B.5.5 - Smoke
CCTV 400-75-FR6220-05-601 - Toxic Fume Emission
LMR 600 FRBS EN 61034-2 (2005)22/10/2010ExovaDanish RailSmoke Density
LMR 600 FRIEC 60332-3-24 Cat C26/11/2010ExovaDanish RailVertical Flame propogation
LMR 600 FRIEC 60332-1-2 (2004)22/10/2010ExovaDanish Rail"Single" flame propgation
LMR 600 FRLUL code of practice comprises:20/11/1995LULLondon UndergroundSmoke , Toxic Fume , Flammability
LMR 600 FRBS 6853 : 1987 App A - Flammability
LMR 600 FRBS 6853 : 1987 App B.5.5 - Smoke
LMR 600 FR6220-05-601 - Toxic Fume Emission
LMR 600 FR-UFBS EN 61034-2 (2005)22/10/2010ExovaDanish RailSmoke Density
LMR 600 FR-UFIEC 60332-1-2 (2004)22/10/2010ExovaDanish Rail"Single" flame propgation
LMR 600 FR-UFIEC 60332-3-24 Cat C26/11/2010ExovaDanish RailVertical Flame propogation
LMR 1200 FRLUL code of practice comprises:20/11/1995LULLondon UndergroundSmoke , Toxic Fume , Flammability
LMR 1200 FRBS 6853 : 1987 App A - Flammability
LMR 1200 FRBS 6853 : 1987 App B.5.5 - Smoke
LMR 1200 FR6220-05-601 - Toxic Fume Emission
"FR" JACKET "Common"NF X70-100-1 (2006)16/03/2011ExovaDanish RailJacket Gas analysis
(sample LMR195-FR)NF X70-100-2 (2006)16/03/2011ExovaDanish RailJacket Gas analysis
"FR" DIELECTRIC "Common"NF X70-100-1 (2006)16/03/2011ExovaDanish RailDielectric Gas analysis
(sample LMR195-FR)NF X70-100-2 (2006)16/03/2011ExovaDanish RailDielectric Gas analysis
"FR" JACKET "Common"NF X70-100-1 (2006)16/03/2011ExovaDanish RailJacket Gas analysis
(sample LMR600-FR)NF X70-100-2 (2006)16/03/2011ExovaDanish RailJacket Gas analysis
"FR" DIELECTRIC "Common"NF X70-100-1 (2006)16/03/2011ExovaDanish RailDielectric Gas analysis
(sample LMR195-FR)NF X70-100-2 (2006)16/03/2011ExovaDanish RailDielectric Gas analysis

New – Cat6 Outdoor Rated & Shielded Cable from Times Microwave

Times Microwave has just released its new CAT6 SFTP LAN Data Cable, 4 pairs 23AWG

Featuring, high coverage tinned copper outer shield for superior grounding, better than 90dB RF Shielding effectiveness, ripcord for easy jacket stripping, 8mm O/D, black PE Jacket for excellent weather resistance.

TMS – Cat-6 Outdoor Rate & Shielded

CAT7 E10 MHz 4-Pair solid S/FTP, Low Smoke, Zero Halogen Cable Violet Jacket

This is a fully shield cable with individual foils around each pair, coupled with high screen
coverage outer braid for a high level of immunity to outside interference’s.
In PoE remote power applications, this cable can be installed in environments up to 60
degrees Celsius without degradation suffered by heat rise inside the cable bundle. This 7A cable
can also be used for cable sharing from one drop ideal for running multiple lower speed
applications.

CAT7A-4PLSZH Cable

LMR Bundled Cable

LMR Bundled Cable

Times Microwave Systems specialises in the design & manufacture of high performance flexible, Low Loss, standard coaxial M17 cable, for RF transmission from HF through to Microwave frequencies DC to 46GHz.

As the exclusive Australian Agent Rojone is pleased to announce the introduction of LMR® Bundled Cable this is a spiral configuration of multiple LMR®-400 or smaller LMR® cables under a common polyethylene outer jacket. This innovative design acts as the perfect feeder cable for applications requiring multiple runs, such as on towers or building top sites. A unique, patented grounding fixture grounds the outer shields of each cable and a rugged end cap seals the bundle to prevent moisture ingress at the break-out point.

LMR © Bundled Cable can be supplied as complete assembly with break outs and connectors on both ends, and as a single ended assembly (base can be trimmed and terminated after installation on tower), or as a raw cable and accessories along with easy to use tools. Pictorial instructions and installation videos are available to assist in the installation of the accessories.

Features and Benefits:

  • Less Cable Runs
  • Fewer Ground Kits and Cable Clamps to Install
  • Reduced Labour and Material Costs
  • Rip cord for easy removal of outer jacket
  • Inner cables labelled with an identifier every six inches

Standard Cables Include:

  • LMR-BC240-4
  • LMR-BC300-12
  • LMR-BC240-9
  • LMR-BC400-7
  • LMR-BC240-9-LW-75
  • LMR-BC400-9
  • LMR-BC-240-12
  • LMR-BC400-9-DB

LMR Bundled Cable (2MB)

EC-BC Series End Cap Kits

Times Microwave Systems offers weather seal break out caps for a number of the LMR bundled cables. These kits consist of a hard ABS plastic split shell with stainless steel screws, a silicone rubber split cushion and a silicone rubber gasket. The split cushion is formed over the inner cables and the shell is then positioned over the transition so that the end of the outer jacket of the cable is roughly in the middle of the shell.

Watch the video below to see how to install the EC-BC Series End Cap Kit.
http://www.youtube.com/watch?v=W0CmQJmX6Ew

Semi Rigid Coax Cables

Click here to download a printable copy of this table

 

Military Standard Semi-Rigid Coax Cables

Cable CodeNominal Imped.Capac. pF/ftCapac. pF/mDielec. MaterialConduct. Size (in.) & TypeShield TypeOuter Dim. (in.)Outer Dim. (mm.)Weight (kg/100m)Min. Bend Radius (in.)Min. Bend Radius (mm.)Notes
M17/129-RG4015029.697.1PTFE0.0641 SCBC TUBE0.256.3515.60.1253.175SWEPT ATTN & SRL FROM 400-18,000MHZ
M17/129-000015029.697.1PTFE0.0641 SCTC TUBE0.256.3515.60.1253.175TIN PLATED M17/129-RG401
M17/130-RG4025029.998.1PTFE0.0362 SCCSBC TUBE0.1413.585.120.0751.905SWEPT ATTN & SRL FROM 500-20,000MHZ
M17/130-000015029.998.1PTFE0.0362 SCCSTC TUBE0.1413.585.120.0751.905TIN PLATED M17/130-RG402
M17-130-000025029.998.1PTFE0.362 NCCCSBC TUBE0.1413.585.120.0751.905SWEPT ATTN & SRL FROM 500-20,000MHZ
M17/130-000035029.998.1PTFE0.0362 NCCCSTC TUBE0.1413.585.220.0751.905TIN PLATED M17/130-00002
M17/130-000045029.998.1PTFE0.362 SCCSBC TUBE0.1413.585.120.0751.905SWEPT ATTN & SRL FROM 500-20,000MHZ
M17/130-000055029.998.1PTFE0.0362 SCCSTC TUBE0.1413.585.220.0751.905TIN PLATED M17/130-00004
M17/130-000065029.998.1PTFE0.362 NCCCSBC TUBE0.1413.585.120.0751.905SWEPT ATTN & SRL FROM 500-20,000MHZ
M17/133-RG4055032105PTFE0.0201 SCCSBC TUBE0.08652.22.280.051.27SWEPT ATTN & SRL FROM 500-20,000MHZ
M17-133-000015032105PTFE0.0201 SCCSTC TUBE0.08652.1972.350.051.27TIN PLATED M17/130-RG405
M17/133-000065032105PTFE0.0201 SCCSBC TUBE0.08652.1972.280.051.27SWEPT ATTN & SRL FROM 500-20,000MHZ
M17/133-000075032105PTEF0.0201 SCCSTC TUBE0.08652.1972.350.051.27TIN PLATED M17/133-00006
M17/151-000015032105PTFE0.0113 SCCSBC TUBE0.0471.1940.60.051.27SWEPT ATTN & SRL FROM 500-20,000MHZ
M17/151-000025032105PTFE0.0113 SCCSTC TUBE0.0471.1940.60.051.27TIN PLATED M17/151-00001

 

Standard Cable 0.087″ 0.141″
CNC Fomers 6.4 mm 8 mm
Radiuses 10 mm 10 mm / 12.5 mm

Custom sizes available

Abbreviations

SC Silver-Covered Copper
SCCS Silver-Covered Copper-Clad Steel
NCCCS Nickel-Covered Copper-Clad Steel
BC TUBE Bare Copper Tube
TC TUBE Tinned Copper Tube
PTFE Polytetrafluoroethylene

 

Data Cable – Cat 5, Cat 6, Cat 7

The fundamental importance of the Data Centres and the need to provide for daily increasing applications, transmission speeds and data storage, businesses are investing in the amount of equipment their Data Centres must support. Consequently, IT managers must design scalable Data Centres to support their future growth and potentially new technologies, while ensuring the best performance.

Rojone supplies high quality Data cables consist of Cat.5e to Cat.7A multi-cable, multi-pair and multi-core structures solid and matched work area cables.

All cables are fully compatible with the standard connecting hardware (i.e. RJ-45).

All products are available with FR-LSZH, PVC, PU and PE jackets combined with different optional shielding structures such as S/FTP, SF/UTP, F/UTP, U/FTP.

The cables are designed with optimised lay lengths, size, transmission performance and structures to enable peak high density data-centre cabling.

High-density cabling creates less congestion in pathways which means better cooling conditions in particular for PoE and PoE+ applications, lower installation time, minimises down time, accelerates recovery time, minimises site access by non-essential personnel, and allows place-and plug modular installation for Gigabit and up to 10 Gigabit applications.

Category 5e, 100 Ohm

100 MHz Data Transmission Cables

The basic solution is a complete line of high-performance 100 Ohm cables, conforming to Category 5e in accordance with TIA/EIA-568-C, ISO/IEC 11801, IEC 61156-5, IEC 61156-6 and CENELEC prEN 50288, supporting CLASS D (new) Links.

The product range includes Horizontal, Working area (Patch) and Backbone Cables, available in a wide range of constructions, including U/UTP, F/UTP, SF/UTP and S/FTP.

All cables are available with PVC, PU (Polyurethane), PE (Polyethylene) and FR-LSZH (Flame Retardant Low Smoke Zero Halogen) jackets, in single or “Siamese twin” (FIG-8), multi-cable, or multi-core constructions.

Category 5e Data Transmission Cables

Part NumberProduct DescriptionComputer & LAN ApplicationsOuter Jacket MaterialOuter Diameter (mm nom.)
4T00080101Cat. 5e 4x2x24/1 AWG U/F/UTP + 17 AWG CCS Fig-8 Double Jacket Outdoor UL1581-VW1/CMX Jacket Outdoor UL1581-VW1/CMXOutdoor installationsUV resistant FR-PVC7.9
8393204xxxCat. 5e 4x2x24/1 AWG F/UTP Outdoor PVC/PVC UL (1581 VW 1) (UL) LISTED E211498Outdoor installationsUV resistant FR-PVC7.9
7272604xxxCat. 5e 4x2x26/7 AWG Work Area U/UTP PVCIndoor use, fixed or portable installationsFR-PVC4.9
8272626xxxCat. 5e 4x2x26/7 AWG F/UTP Work Area PVCWork area cablingFR-PVC5.70
9292604xxxCat. 5 4x2x26/7 AWG SF/UTP Work Area PVCWork area cablingFR-PVC5.3
7562004xxxCat. 5e 4x2x24/1 AWG U/UTP PVCIndoor use, fixed installationsFR-PVC5.0
7568204xxxCat. 5e 2x(4x2x24/1 AWG) FIG-8 U/UTP PVC P Fig-8Indoor use, fixed installationsFR-PVC5.1
8371204xxxCat. 5e 4x2x24/1 AWG F/UTP PVCIndoor use, fixed installationsFR-PVC6.1
8391304xxxCat. 5e 4x2x24/1 AWG F/UTP Outdoor Low Temperatures PVCIndoor/Outdoor use, fixed installationsUV resistant
FR-PVC
7.2
8371804xxxCat. 5e 2x(4x2x24/1 AWG) FIG-8 F/UTP PVC TrunkingFR-PVC6.1
8371406xxxCat. 5e 6x(4x2x24 AWG F/UTP) Multi-Cable PVCIndoor use, fixed installationsFR-PVC20
8371412xxxCat. 5e 12x(4x2x24 AWG F/UTP) Multi-Cable PVCIndoor use, fixed installationsFR-PVC27.6
8371425xxxCat. 5 25x(4x2x24 AWG F/UTP) Multi-Cable PVCTrunk Cable for Local Area NetworksFR-PVC35.5

Category 6, 100 Ohm

250 MHz Data Transmission Tables

The GIGA-STAR Solution is a complete line of data-transmission cables horizontal and work area types, designed for Cat. 6 and Cat. 5e for use in CLASS D and CLASS E cabling systems.

GIGA-STAR cables are tested up to 300 MHz, and are fully compatible with ISO/IEC 11801, IEC 61156-5, IEC 61156-6, and TIA/EIA 568C.

The GIGA-STAR Solution is consists of the following three groups:

  • U/UTP cables, where high NEXT and FEXT loss values are achieved by mechanical pair separation
  • U/FTP cables, where high NEXT and FEXT loss values are achieved by individual pair shielding
  • S/FTP cables, where an additional overall braid shield provides outstanding EMC performance

Our customers have the option of selecting a true Category 6 cable that meets all the transmission parameters required to support the advanced applications with 3 different levels of EMC performance:

  • U/UTP cables: 50 dB coupling attenuation
  • U/FTP cables: 75 dB coupling attenuation
  • S/FTP cables: 85 dB coupling attenuation

All GIGA-STAR cables feature high values of PS-ACR and PS-ELFEXT, and a stable 100 Ohm characteristic impedance ensuring very low Return-Loss, making The GIGA-STAR Solution ideal for GIGABIT-Ethernet applications. All cables are available with a PVC or Flame Retardant Low-Smoke Zero-Halogen (FR-LSZH \ HFFR) jacket and in a single or “Siamese twin” (FIG-8) construction.

Category 6 Data Transmission Cables

Part NumberProduct DescriptionComputer & LAN ApplicationsOuter Jacket MaterialOuter Diameter (mm nom.)
720KZ04xxxCat. 6 4x2x24/7 AWG U/UTP Work Area PVCHigh bandwidth digital applications with low BERFR-PVC6.5
9828022xxxCat. 6 4x2x26/7 AWG U/FTP Work Area PVCHigh bandwidth digital applications with low BERFR-PVC6.3
9828026xxxCat. 6 4x2x26/7 AWG S/FTP Work Area PVCHigh bandwidth digital applications with low BERFR-PVC6.4
750AZ04xxxCat. 6 4x2x23/1 AWG U/UTP PVCIndoor use, fixed installationsFR-PVC6.7
750BZ04xxxCat. 6 4x2x23/1 AWG U/UTP FRLSZHData-Centers/SANsFR-LSZH6.6
750BZR4101Cat. 6 4x2x23/1 AWG U/UTP SWA Outdoor Direct Burial LSZHTrunk Cable for Local Area NetworksUV resistant PO compound12.7
750UZ04xxxCat. 6 4x2x23/1 AWG U/UTP Indoor/Outdoor FR-LSZH/FR-LSZHLow temperature Indoor/Outdoor applicationsFR-LSZH8.3
8300204xxxCat. 6 4x2x23/1 AWG U/FTP FRLSZHIndoor use, fixed installationsFR-LSZH7.3
8300804xxxCat. 6 2x(4x2x23/1 AWG) FIG-8 U/FTP FR-LSZHTrunk Cable for Local Area NetworksFR-LSZH7.6
8300904101Cat. 6 4x2x23/1 AWG U/FTP Outdoor LSZHIndoor/Outdoor use, fixed installationsFR-LSZH9.6
8300C04101Cat. 6 4x2x23/1 AWG U/FTP CSA FR-LSZH/PEOutdoor and direct burial installationsUV Resistant FR-PO13.2
830D104xxxCat. 6 4x2x23/1 AWG U/FTP Drop PVCTrunk Cable for Local Area NetworksUV resistant FR-PVC7.4

Category 6A, 100 Ohm

500 MHz Data Transmission Cables

Giga-Ten Solution cables is a complete line of data-transmission horizontal and work area cables, designed for state-of-the-art cabling systems including Class EA of ISO/IEC 11801 and Cat. 6A of IEC 61156-5/6.

These cables are tested up to 650 MHz, and are fully compatible with the ISO/IEC 11801, IEC 61156-5, IEC 61156-6, and TIA/EIA 568C.

Cat. 6A cables come in the following designs:

  • U/FTP cables grounded, where high AXT, NEXT and FEXT attenuation values are achieved by individual pair shielding
  • U/FTP cables ungrounded, where high AXT, NEXT and FEXT attenuation values are achieved by individual pair shielding. These cables may be terminated with non-shielded connecting hardware with out any performance or EMC issues
  • F/FTP cables, where high AXT, NEXT and FEXT attenuation values are achieved by both overall and individual pair aluminium foil shields
  • S/FTP cables, where high AXT, NEXT and FEXT attenuation values are achieved by both overall copper braid and individual pair aluminium foil shields. This structure is recommended for PoE (Power over Ethernet) applications

Giga-Ten Cat. 6A Solution cables have Coupling Attenuation complying with Type II and Type I (depending on shield design) requirements per IEC 61156-5/6 therefore AXT performance is proven by design.

The cable’s high values of PS-ACR and PS-ELFEXT attenuation, and a stable 100 Ohm characteristic impedance ensuring very low Return-Loss, make it ideal for 1 and 10 GIGABIT-Ethernet applications.

All cables are available with a PVC or Flame Retardant Low-Smoke Zero-Halogen (FR-LSZH \ HFFR) jackets as well as other compounds, and in single or “Siamese twin” (FIG-8) constructions.

Category 6A Data Transmission Cables

Part NumberProduct DescriptionComputer & LAN ApplicationsOuter Jacket MaterialOuter Diameter (mm nom.)
9828U22xxxCat. 6A 4x2x26/7 AWG U/FTP Ungrounded U/UTP use Workarea FRLSZHHigh bandwidth digital applications with low BERFR-LSZH6.1
9828U61xxxCat. 6A 4x(2x24/1 AWG) U/FTP ungrounded FR-LSZHIndoor use, fixed installationsFR-LSZH6.4
9828U71xxxCat. 6A 4x(2x24/1 AWG) U/FTP ungrounded FR-PVCIndoor use, fixed installationsFR-PVC6.4
9828G22xxxCat. 6A 4x2x26/7 AWG U/FTP Work Area FR-LSZHHigh bandwidth digital applications with low BERFR-LSZH6.0
9828G24xxxCat. 6A 4x2x0.45/1 mm U/FTP Work Area FR-LSZHHigh bandwidth digital applications with low BERFR-LSZH6.3
83U0204xxxCat. 6A 4x2x23/1 AWG U/FTP Ungrounded U/UTP use FR-LSZHIndoor use, fixed installationsFR-LSZH7.4
83UM204xxxCat. 6A 4x2x23/1 AWG U/FTP Ungrounded U/UTP use FR-LSZH IEC 60332-3Indoor use, fixed installationsFR-LSZH8.0
83G0204xxxCat. 6A 4x2x23/1 AWG U/FTP FR-LSZHIndoor use, fixed installationsFR-LSZH7.3
83G0208xxxCat. 6A 2x(4x2x23/1 AWG) FIG-8 U/FTP FR-LSZHIndoor use, fixed installationsFR-LSZH7.3
83GU204xxxCat. 6A 4x2x23/1 AWG U/FTP Indoor/Outdoor FR-LSZH/HFFR-PUIndoor/Outdoor use, fixed installationsFR-PVC9.0